Sample Indoor Air Quality Report

Written report

This is what your report looks like

These pages are from a real illumenair report on a two-story Portland-area home, with the client's details removed. Every report opens the same way: the areas that need attention and what to do next, in plain language, before any raw data. The written report follows within 48 hours of the visit.

illumenairIndoor air quality
Interpretive summary

Summary

Sample Client · Two-story home, Portland metro · Sample report, client details removed · Jim Gray, Assessor

Mold Readings: Areas Requiring Attention

AreaResting (p/m³)Resuspension (p/m³)
Primary bathroom30,36221,000
Primary closet22,587190,000
Landing office11,73859,000
Upstairs office13,60240,000
Primary bedroom8,74438,000
Primary bathroom drain & under cabinet26,37711,000
Laundry12,11525,000
Upstairs bathroom drain & under cabinet18,8756,100
Laundry drain & perimeter17,89818,000

Outdoor baseline: 2,647 p/m³. Resuspension readings are as reported on the Area Result Summaries, rounded to two significant figures.

Overall Summary

The inspection identified elevated mold levels in several areas of the home. The primary bathroom measured 30,362 p/m³ in resting air, the highest resting reading in the house, and the Deep-Dive found what appears to be a roof leak over that bathroom and a leaking toilet seal.

The primary closet, both offices and the primary bedroom read moderately at rest but rose sharply when settled dust was disturbed, most notably the primary closet at 190,000 p/m³ on resuspension. That pattern points to spores held in carpet and settled dust rather than a separate source in each room. VOC and CO₂ levels were also elevated in several areas. Conditions like this are common and generally addressable with the steps outlined below.

How to read these numbers

There is no legal "safe" or "unsafe" limit for indoor mold, so every mold reading is measured against the outdoor air sampled at the property that day, 2,647 p/m³. Readings near or below it are typical; readings well above it are flagged as elevated. Resting is the air as found; resuspension measures what settled material adds to the air when the space is in use.

Other measurements compare against published limits, within range at or below and flagged above: CO₂ 1,000 ppm · VOC 400 ppb · Humidity 50% · PM2.5 35 µg/m³ · PM10 150 µg/m³.

Illumenair Environmental Assessment · Portland · Vancouver · SW WashingtonPrepared by Jim Gray · info@illumenair.com

Other Flagged Parameters

AreaParameterReadingNote
All indoor areasVOC529 to 670 ppbAbove the 400 ppb advisory; outdoor 281 ppb
14 of 17 indoor areasCO₂1,007 to 1,605 ppmAbove 1,000 ppm (ventilation)
Primary bathroom and drain areaHumidity53%Above 50%; other areas 44 to 49%

Mold & Moisture Deep-Dive

There appears to be a roof leak over the primary bathroom. The primary toilet rocks, and its wax seal is broken.

Suggested Next Steps

  1. Consider having a roofing contractor investigate and repair the leak.
  2. Consider having a plumber solve the rocking issue (the floor may not be level, the toilet may have a low spot hitting the flange, or the flange may have a high spot) and then reseat the toilet.
  3. Consider cleaning the carpets in the areas of elevated mold readings.
  4. Consider airing out the house often to lower VOC and carbon dioxide levels.
  5. Consider a follow-up assessment after the repairs and cleaning, to confirm the change.

Scope and Limitations

These measurements describe airborne particles at the moment of sampling and do not evaluate growth within wall cavities or beneath flooring.

Illumenair Environmental Assessment · Portland · Vancouver · SW WashingtonPrepared by Jim Gray · info@illumenair.com
illumenairIndoor air quality
Mold comparison

Scan-by-Scan Mold Comparison

This chart shows each area's resuspension mold reading, with its resting (quiescent) reading in the right-hand column, in particles per cubic meter (p/m³). Resuspension measures what settled material adds to the air when a space is in use. The outdoor baseline is the resting outdoor reading, shown for reference.

Outdoor baselineResuspension readingResuspension reading at or above 40,000 p/m³

Resuspension readings are as reported on the Area Result Summaries, which round to two significant figures.

Illumenair Environmental Assessment · Portland · Vancouver · SW WashingtonPrepared by Jim Gray · info@illumenair.com
Welcome and what we measure

All ten parameters explained, and the limits of what airborne testing can and cannot tell you.

Scan-by-scan comparisons

Charts for mold, bacteria, VOCs, CO₂ and particulates across every area, side by side.

Area Result Summaries

One page per area with the full reading set, resting and resuspension, against the outdoor baseline.

Download the full sample report (PDF)

21 pages · a real Portland-area assessment · client details removed

Every Assessment Includes

What comes in every report

No matter the property size, every illumenair assessment delivers the same complete documentation package.

01

Room-by-Room Data

Individual readings for every tested area — bedrooms, bathrooms, kitchen, living spaces, and finished basements. Not a single whole-home average.

02

Outdoor Baseline Comparison

Every indoor reading is measured against a simultaneous outdoor baseline. This reveals true indoor/outdoor ratios — the only way to know if your inside air is genuinely worse than outside.

03

Parameter Breakdown

Separate data tables for all 10 core parameters — mold, bacteria, viral load, pollen, VOCs, carbon monoxide, CO₂, humidity, PM2.5, and PM10 — across every room and both quiescent and resuspension scans.

04

Source Identification

Where possible, likely contamination sources are noted — HVAC distribution, basement moisture intrusion, volatile materials, cooking byproducts. Context that turns data into answers.

05

Prioritized Action Plan

A sequenced list of recommendations — what to fix first, why, and what to expect from each intervention. We don't just hand you data and walk away.

06

Provider-Ready Format

The written report is formatted for clinical records — ready to share with your primary care physician, naturopath, integrative MD, or remediation contractor. Supports Shoemaker Protocol documentation.

Schedule Your Assessment

Know what's in your air.

Contact us to schedule your residential or commercial air quality assessment. We serve Portland, Vancouver, Ridgefield, and southwest Washington.

Portland · Vancouver · Ridgefield · SW Washington

Call (971) 363-5626 Request Testing